DT9829

In stock
SKU
DT9829
S$2,800.00

DT9829

USB Multi-Sensor Measurement Module
Software-Selectable Precision Measurement for Any Sensor

Direct connection of many types of sensors –
software‑selectable per channel
o Thermocouples: B, E, J, K, N, R, S, and T types
o RTD: Pt100, Pt500, Pt1000 – 2‑, 3‑, and 4‑wire
o Thermistors: 2‑, 3‑, and 4‑wire
o Bridge‑based sensors: internal 3.0 VDC
excitation, ±200 mV input range
o Voltage: ±10 V,±2 V,±200 mV input range
o Current: ±25 mA
o Resistance: 0 kΩ to 200 kΩ, 2‑, 3, and 4‑wire
o 3‑wire configurations provide lead wire
compensation
• Software‑selectable sensor type and parameters to
configure, record and analyze each channel in 3 easy
steps (see page 2)
• Each input channel independent – no interactions
between sensors on any channel
• Sample rates to 960 S/s
• 24‑bit sigma‑delta ADC eliminates aliasing for
extremely accurate measurements
• Thermocouple CJC and open circuit detection
• 4 isolated digital inputs and digital outputs
• ±500 V galvanic isolation to PC and ground
• USB 2.0 powered – no extra power supply needed

DT9829

USB Multi-Sensor Measurement Module
Software-Selectable Precision Measurement for Any Sensor

The DT9829 is a portable data acquisition multi‑sensor
measurement module for USB. Use the DT9829 software
to select from many sensor types and their parameters:
voltage inputs, current, thermocouples, RTDs,thermistors,
resistance, bridge‑based sensors, and strain gages.

Analog Input Channels
The DT9829 supports 8 differential analog input channels
that are multiplexed to a single 24‑bit Delta‑Sigma
A/D converter on the module, providing outstanding
accuracy. Each analog input channel can accept any
one of the following sensor types: voltage, current,
thermocouple, RTD, resistance, thermistor, bridge‑based
sensors, or strain gage. Channel configuration is done
completely through software, making set‑up simple

More Information
Number of input Channels 8
Signal Type Differential
Multi Sensors RTD, Thermocouple, NTC, Current, Voltage, Resistance, Bridge
Sensor Specification

RTD: Pt100, Pt500, Pt1000 – 2‑, 3‑, and 4‑wire

Thermocouples: B, E, J, K, N, R, S, and T

Thermistors: NTC, 2‑, 3‑, and 4‑wire

Current: ±25 mA

Voltage: ±10 V,±2 V,±200 mV

Resistance: 0 Ω to 200 kΩ, 2‑, 3, and 4‑wire

Bridge‑based sensors: internal 3.0 VDC excitation, ±200 mV input range

Range N/A
Galvanic Isolation 500 V
A/D Resolution 24 bit
Max Sampling 960 S/s
Digital IO

4 input

4 output

LAN port No
LXI Instrument No
Host Interface USB2
Software Packages
  • QuickDAQ
  • DAQ Adaptor for MATLAB 
  •  LV-Link — Access the power of Data
    Translation boards through LabVIEW™.
  • QuickDAQ FFT Analysis  (License Required)
  • QuickDAQ Advanced FFT Analysis (License Required)

 

Dimensions N/A
Manufacturer Data Translation
DT9829 Data Sheet
(Size: 2.4 MB)