DT9874-16T-16R-16V

In stock
SKU
DT9874-16T-16R-16V
S$14,580.00

DT9874-16T-16R-16V

48 Ch, 24 bit, Mixed Sensors,  Thermocouple, RTD, Voltage,USB

 
• ISO-Channel™ technology provides galvanic isolation
channel-to-channel and to earth ground.
• Dedicated 24-bit: Delta-Sigma ADC/channel
• 48 differential (DIFF)  simultaneous analog inputs
• Sampling rate: up to 10 S/s/ch
• Auto-calibrating front-end: resets the zero point on each power-up
• Measurement Instrument Calibration Utility: allows in-field calibration
• Digital I/O galvanically isolated to 250 V: 8 in/8 out
Analog Input Channels 0 to 15: Thermocouple
Analog Input Channels 16 to 31: RTD
Analog Input Channels 31 to 48: Voltage
 

DT9874-16T-16R-16V

48 Ch, 24 bit, Mixed Sensors,  Thermocouple, RTD, Voltage, USB

 
• ISO-Channel™ technology provides galvanic isolation
channel-to-channel and to earth ground.
• Dedicated 24-bit: Delta-Sigma ADC/channel
• 48 differential (DIFF)  simultaneous analog inputs
• Sampling rate: up to 10 S/s/ch
• Auto-calibrating front-end: resets the zero point on each power-up
• Measurement Instrument Calibration Utility: allows in-field calibration
• Digital I/O galvanically isolated to 250 V: 8 in/8 out


Analog Input Channels 0 to 15: Thermocouple
− Configurable channels for thermocouple or differential voltage inputs; easy-access
jacks for each channel for quick wiring
− One CJC (cold junction compensation) input for each thermocouple channel
− B, E, J, K, N, R, S, and T thermocouple types supported; the instrument automatically
linearizes the measurements and returns the data as a 32-bit, floating-point
temperature values
− Input range of ±0.075 V (with 0.25 μV RMS A/D noise using no software filtering)
− Break-detection circuitry to detect open thermocouple inputs

Analog Input Channels 16 to 31: RTD
− Configurable analog input channels for RTDs and differential voltage inputs;
easy-access jacks for each channel for quick wiring
− 100 Ω, 500 Ω, and 1000 Ω platinum RTD types supported using alpha curves of 0.00385
(European) or 0.00392 (American)
− 4-wire, 3-wire, or 2-wire configurations; the DT8872 automatically linearizes the
measurements and returns the data as 32-bit, floating-point temperature, resistance, or
voltage values
− Input range of ±1.25 V

Analog Input Channels 31 to 48: voltage
− Direct connection of analog input channels for differential voltage inputs; removable
screw terminal blocks for each channel for quick wiring
− Software-selectable input range of ±10 V, ±100 V, or ±400 V per channel

More Information
Number of input Channels 48
Signal Type Differential
Multi Sensors RTD, Thermocouple, Voltage
Sensor Specification

Thermocouples:  B, E, J, K, N, R, S, and T

RTD: PT100, PT500, PT1000, 2, 3, 4 wires

Voltage: ±10 V, ±100 V, or ±400 V

Range –100° C to +1400° C
Galvanic Isolation 500 V
A/D Resolution 24 bits
Max Sampling 10 S/s
Digital IO

8 input

8 output

LAN port No
LXI Instrument No
Host Interface USB2
Software Packages

QuickDAQ

QuickDAQ FFT Analysis Option (License
Required)
• QuickDAQ Advanced FFT Analysis Option
(License Required

Manufacturer Data Translation
Write Your Own Review
You're reviewing:DT9874-16T-16R-16V
Your Rating